Real Estate ListingsData Center ListingsMidwest Region Data Center725 S. Wells Street,Chicago,IL
Building Size (RSF): | 54,400 RSF / 8 stories | SF Available: | 24,360 SF (divisible) | Floor Size: | 6,800 square feet (400 bKW to 750 bKW per floor) | Floor Loading: | Reinforced slab;250 lbs | Fiber: | AT&T,SBC,Level 3,Looking Glass Networks,Qwest,Above Net,XO,Yipes,Cogent. Three diverse fiber entrances. | Cabinet Space: | Approx. 165 Cabinets per floor | UPS Power: | Equipment size installed at 750 KW,N+1 configuration breaker power per floor;Optional 2N UPS configuration | Generator: | Configuration flexible from N to 2N | Cooling: | Central Plant Chilled Water | Fire Protection: | Double Interlock Pre-Action with Heat &Smoke Detection. Optional VESDA and Gas Suppression | Raised Floor:Security: | 24”Card Key and biometric access |
1800 Springer Road,Lombard,IL
SF Available: | 600 KW,6,400 sf -Phase II,Available (divisible) | Floor Loading: | 250+ lbs/sf | Fiber: | Carrier neutral facility – multiple fiber carriers available including AT&T and AboveNet | Clear Height: | 15’9” | UPS Power: | | Generator: | Three (3) 800 KW diesel generators (fourth generator can be added) | Cooling: | Eight (8) 30 ton chilled water based CRAC units | Raised Floor: | 36” | Security | Biometric security access,video surveillance,on-site security 24x7x365 |
210 N. Trucker,St. Louis,MO
Building Size: | 201,588 SF – 18 story | SF Available: | 60,000 SF | Dedicated Suites: | 1,000 SF to 20,000 SF | Floor Loading: | 78 PSF / Reinforced to 150 PSF | Fiber: | Level(3),AT&T,Verizon,XO,AboveNet,Sprint,Charter,Qwest,Paetec | UPS Power: | Multiple N+1 UPS and Dedicated PDU’sScalable from 400 to 1200 kW Systems2N Configuration Available | Generator: | Standby Generators with Base Tanks24-hr Runtime | Cooling: | Base Building Condenser Water | Security | Station for 24/7 on site security;Key card access control,cameras,biometric reader |
California Data Center Listings1100 Market Street,Sacramento
Year Built: | 1999 | SF Available: | 92,200 SF (52,500 SF raised floor) | Raised Floor Available: | 22,500 SF – 24” raised floor | Floor Loading: | Slab on Grade | Fiber: | AT&T,Level 3,Cogent,Integra,MCI,Verizon,Comcast,Qwest,SBC,Surewest,Global Crossing,TW telecom and XO | Clear Height: | 24’0” | UPS Power: | Ten (10),UPS units (N+2) and thirty three (33) PDU’s (N+1) | Generator: | Four (4),2 MW diesel generators (N+1) | HVAC: | 77 down flow 30-ton CRAH units to cool raised floor | Fuel Tank: | Two (2),8,000 gallon fuel tanks | Parking: | 237 surface parking spaces |
600 Wilshire Boulevard,Los Angeles,CA
Floor Plates: | 18,850 SF | Power: | 24 MVA supplied by 34.5 kV feed | Fire Systems:: | UL-Listed fire alarm system;System is set up to support installation of pre-action sprinkler systems on data center floors | Security: | 24 hour security guard service;interior and exterior digital cameras;security card access system |
Northeast Region Data Center Listings1500 Queen Anne Road,Teaneck,NJ
Building Size: | 56,000 SF | Raised Floor: | 31,500 SF of raised floor space | Floor Loading: | Slab on Grade | Power: | 10 MW already installed | Clear Height: | 16’0” | Fuel Storage: | 10,000 gallon fuel storage tank | Security | Fully fenced and secure site;complete exterior and interior camera coverage;card access control at all secure areas; |
Deep Run Corporate Campus,Central New JerseyCampus: | 275 acres | Power: | 80 MW at 115 kV | Floor Loading: | 200 w/sf | Security | Gated entrance;single point access |
Southwest Region Data Centers1615 Garden of the Gods,Colorado Springs,CO
Year Built: | 1996 | Building Size: | 710,789 SF | Floor Loading: | In excess of 200 lbs/sf | Power: | 35 MW capacity |
Harmony Technology Park,Fort Collins,CO
Land area:: | 40+ acre Greenfield opportunity | Power: | 40+ megawatts,expandable | Fiber: | Fort Collins and the Harmony Technology Park offer superb connectivity with the access to telecom infrastructure from multiple providers. At this site,the providers offer physical diversity of their fiber as well as access to regional rings,and direct access to the gateway. |
Southeast Region Data Centers6855 Crescent Drive,Norcross,GA
Building Size: | 43,472 SF | SF Available: | 30,000-35,000 SF | Cabinets: | Can be configured to support 500 to 700 IT cabinets | Electrical and Generator: | Pads and conduit for two (2),3,000 A electrical service and 1750 kW generator | Cooling: | Thirteen (13),20 ton Liebert DX up flow CRAC units with condensing units on the roof are installed and available for Tenant use | Fiber: | Building has four (4) diverse and separate fiber entrance facilities and is served by Level 3 and Bell South | Security | Entire property is fenced with gated entrance |
1309 N. Ward Street, Tampa, FL SF Available: | 23,500 SF 2 story single tenant | Raised Floor: | 9,000 SF | Electrical: | Original service 3000 Amp @ 480Y/277V Supplemental service 1600A @ 480Y/277V | Cabinets: | 242 Wrightline Cabinets (24″x 42″) | Cooling: | Two (2) Chilled water systems 428 tons each 25,000 gallon nake-up water on storage tank | Workforce Recovery Space: | 7,500 SF | Security | Site secured by access control,surveillance system and perimeter fence |
| |